Arrow Refrigerated
Dryers
| Model |
scfm@
35 F Dew Point |
scfm@
50 F Dew Point |
Air
Line Connection |
Voltage |
Condenser
Type |
Height |
Weight |
Length |
Wt.
Lbs |
KW
Input
|
|
F05/10 |
10 |
12 |
3/8"
O.D |
1,2 |
Air |
13.5 |
13 |
15 |
50 |
.20 |
|
F10/20 |
20 |
25 |
1/2"
NPT |
1,2 |
Air |
13.5 |
13 |
18 |
58 |
.26 |
|
F30/40 |
40 |
50 |
1/2"
NPT |
1,2 |
Air |
16 |
14 |
22 |
78 |
.40 |
|
F50 |
50 |
62 |
1"
FPT |
1,2 |
Air |
16 |
14 |
22 |
78 |
.48 |
|
F70/100 |
100 |
124 |
1"
FPT |
1,2 |
Air |
27.5 |
20 |
30 |
163 |
.51 |
|
F125 |
125 |
156 |
1"
FPT |
1,2 |
Air |
31.5 |
27 |
34.5 |
278 |
1.28 |
|
A150 |
150 |
175 |
2"
MPT |
1,2,4 |
Air,
Water |
42 |
29 |
38 |
398 |
1.34 |
|
A-200 |
200 |
240 |
2"
MPT |
1,2,4 |
Air,
Water |
42 |
29 |
38 |
435 |
1.34 |
|
A-300 |
300 |
350 |
2"
MPT |
2,3,4 |
Air,
Water |
42 |
29 |
38 |
505 |
.37 |
|
3512 |
340 |
420 |
3"
NPT |
3,4,5 |
Air,
Water |
44.5 |
38 |
42 |
716 |
2.01 |
|
3513 |
375 |
460 |
3"
NPT |
3,4,5 |
Air,
Water |
44.5 |
38 |
42 |
718 |
2.75 |
|
3514 |
500 |
600 |
3"
NPT |
3,4,5 |
Air,
Water |
44.5 |
38 |
42 |
807 |
3.75 |
|
3515 |
625 |
750 |
3"
NPT |
3,4,5 |
Air,
Water |
59 |
38 |
50 |
1136 |
3.75 |
|
3516 |
750 |
900 |
3"
NPT |
3,4,5 |
Air,
Water |
59 |
38 |
50 |
1147 |
3.75 |
|
3517 |
1000 |
1250 |
4"FLG |
3,4,5 |
Air,
Water |
72 |
38 |
50 |
1500 |
7.15 |
|
3518 |
1200 |
1500 |
4"
FLG |
3,4,5 |
Air,
Water |
72 |
38 |
50 |
1500 |
7.15 |
|
3519 |
1600 |
1920 |
6"
FLG |
3,4,5 |
Air,
Water |
87 |
38 |
50 |
1950 |
8.90 |
|
3521 |
2000 |
2400 |
6"
FLG |
3,4,5 |
Air,
Water |
91 |
56 |
72 |
3300 |
11.40 |
|
3548W |
2300 |
2750 |
6"
FLG |
3,4,5 |
Water |
98 |
57 |
80 |
3600 |
8.70 |
|
3522 |
2500 |
3000 |
6"
FLG |
3,4,5 |
Air |
98 |
57 |
98 |
3900 |
14.56 |
|
3523 |
3000 |
3600 |
6"
FLG |
3,4,5 |
Air |
98 |
57 |
98 |
4500 |
18.06 |
|
3549W |
3000 |
3600 |
6"
FLG |
3,4,5 |
Water |
98 |
57 |
98 |
5000 |
13.30 |
|
3524 |
3750 |
4500 |
6"
FLG |
3,4,5 |
Air |
98 |
57 |
98 |
5000 |
19.57 |
|
3550W |
4000 |
5000 |
6"
FLG |
3,4,5 |
Water |
95 |
57 |
80 |
3900 |
16.55 |
|
3560W |
5000 |
5750 |
8"
FLG |
3,4,5 |
Water |
109 |
57 |
80 |
4900 |
16.55 |
|
4041W |
5000 |
5750 |
8"
FLG |
3,4,5 |
Water |
79 |
56 |
140 |
5000 |
24.70 |
|
4042W |
6250 |
7200 |
8"
FLG |
3,4,5 |
Water |
82 |
56 |
141 |
6500 |
26.30 |
|
4043W |
7500 |
8625 |
8"
FLG |
3,4,5 |
Water |
88 |
60 |
140 |
7700 |
37.00 |
|
4044W |
10000 |
11500 |
10"
FLG |
3,4,5 |
Water |
103 |
65 |
150 |
10000 |
32.00 |
|
4045W |
12500 |
14375 |
12
FLG |
3,4,5 |
Water |
108 |
72 |
150 |
13000 |
42.00 |
|
4046W |
15000 |
17250 |
12"
FLG |
3,4,5 |
Water |
120 |
75 |
160 |
15500 |
57.00 |
All capacities above are
based on design conditions of 100 ºF inlet, 100 psig, and
100 ºF ambient.
Semi-hermetic compressor available on all "C" series Cycling
Dryers (Models 3514 thru 3522).
Single or Dual compressor offered or open drive on 4044W, 4045W, and
4046W.
Water regulating valve furnished with all water-cooled units.
KW figures for water cooled
models are 15% less than figures show. Figures include total
electric draw under maximum load, including fan motors, indicators, etc.
Voltage Codes:
|
Standard |
Export |
| 1
-115/1/60 |
100/1/50 |
| 2
-208-230/1/60 |
200-240/1/50 |
| 3
-208-230/3/60 |
200-240/3/50 |
| 4
-460/3/60 |
380/3/50 |
| 5
-575/3/60 |
|
|