Commercial Vacuum
Pumps
Designed to generate and maintain the
vacuum required for "process to operate at peak efficiency." |
|
|
|
|
|
Your
TOTAL source for medical vacuum pump systems |
|
Over 80 years of manufacturing experience
stands behind every Century 2000 Series vacuum pump system. They are designed
and build with the same superior quality, innovation and dependability
that medical facilities have come to expect from us.
Count on quiet, vibration-free operation, with
low overall noise levels. Century 2000 Vacuum Pump Systems include high-output
rotary vane pumps that provide full capacity over the entire vacuum
range. Choose from a variety of horsepower ranges, as well as system
configurations.
Innovative options, such as our exclusive Medi-Trol
Control Panel for duplex systems, let you tailor the system to your
facility;s requirements. The Medi-Trol Sequencing System allows equal
running time on each individual pimp, with visual and audible alarms
for lag unit operation and high temperature conditions.
All Century 2000 Vacuum Pump Systems meet current
NFPA99 vacuum system standards for health care facilities. In addition,
Champion engineers are ready to work closely with you to meet all regulations
and requirements on the state and local level.
- One source from system design through installation
- Worldwide service and support
- Superior quality and reliability
- Meets NFPA 99 Standards
|
|
A Complete
Vacuum Pump
System |
|
Economical
Operation |
| |
- Shipped pre-wired, factory tested and charged with the initial fill
of rotorlub premium lubricant
- Quick and easy installation, just connect the power and vacuum service
to be up and running in no time
- Closed loop coolant/lubricant design eliminated the need for costly
water service and disposal
|
|
- Tailor package response to vacuum pump demand through selectable operating
modes for the most efficient operation.
- Closed loop coolant/sealant system replaces
costly "single-pass" water sealed designs.
- High capacity lubricant filter and separator
elements result in longer intervals between required filter changes.
|
| |
|
|
|
|
|
|
Simplified
Maintenace |
| |
Rotary
Screw Pump End |
|
|
|
|
|
|
|
|
- Uncluttered design with readily accessible components reduces downtime
and service requirements.
- Drive belt maintenace and changes are made asy by the remarkable
simple but practical motor mounting design.
|
| |
- Patented KYPHO rotor profile featuring precision milled tolerances
within .0002" sets the standard for the industry.
- Matched rotors and teh highest quality cylindrical and tapered roller
bearings ensure vibration free operation for extended bearing life.
- Industrial design and conservative operation as a vacuum
pump results
in excellent life expectancies.
|
|
|
|
|
| |
|
Acoustic
Enclosure |
|
|
|
| |
|
- Optional quiet enclosure reduces sound to 78 dBA while allowing
unrestricted access to package components
|
|
|
|
| |
Inlet Valve
With Intellect |
|
|
|
|
|
- Actuator driven butterfly integrated with microprocessor control
yields precise, responsive vacuum control.
- Built-in checking mechanism automatically closes at shutdown to
prevent lubricant siphoning.
- Electro-pneumatic controls, intricate start-up adjustments and frequent
maintenance demands have been eliminated.
|
|
|
| |
|
AirPilot
VP
Microprocessor Control |
|
|
|
| |
|
- More self-diagnostic and shit down capability than any control on
the market.
- Full text operating status and service indicating messages on a
backlit LCD display.
- Precise digital control for instantaneous reaction to varying operational
demands.
|
|
|
|
|
| |
Standard
Equipment |
| |
- Rotary screw vacuum pump end with modulating inlet valce and isolating
check valve
- Attainable base pressur - 29.9 "HgV (.5 TORR)
- 460 v/3 PH/60 HZ, EPAct energy efficient, 3600 RPM, 1.15 SF, ODP
drive motor
- Rigid structural steel base with forklift slits and OSHA approved
drive gaurd
- 10 micron dry-type inlet filter (Shipped Loose)
- 10 micron full flow spin-on type oil filter
- All aluminum, vacuum brazed oil cooler
- ASME pressure relief valvue
- Factory fill RotorLub ROtary Screw Lubricant
- NEMA 12 electrical controls including: Mounted and wired full voltage
starter, AirPilot VP microprocessor controller, Step-down control
voltage transformer.
- AirPilot VP microprocessor control system featuring:
-Selectable Constant Run or Automatic Start and Timed Stop operating
modes with either modulated or Load/No-Load vacuum regulation
-Sequencing capability up to eight packages
-Automatic Restart
-Local gauge correction for installation altitude
-LCD full text display
-Service Advisories for oil, oil filter and inlet air filter
-Protective Shutdowns for motor overload, high and low temperature
conditions, transducer defect or misadjustment in addition to a user-defined
device
- Remote on/off control capability
- Alarm, Package Ready and Package Running relay contacts
- RS-232 Serial Communication Port for communication with external
monitoring systems
- Emergency Stop
|
|
|
|
|
|
Optional
Vacuum Pump
Equipment |
|
|
|
|
|
- Sound Attenuating Quiet Enclosure
- NEMA 4 Controls
- RotorLub Family of Synthetic Lubricants
- Alternate Voltages, TEFC or Premium Efficiency motor
|